50 kW / 110 kWh Office Building Solar Storage with Zero Export in Switzerland
YOTAI PARTNER REFERENCE · YINTU ENERGY SOLUTIONS
The Sarnen office-building reference in YOTAI's collection describes a 50 kW / 110 kWh solar-storage installation. The stated objectives include reducing selected grid-demand peaks, using more local solar and meeting a zero-export requirement at the site connection.
Project at a Glance
| Location | Sarnen, Switzerland |
|---|---|
| Application | Office building |
| Project scale in source | 50 kW / 110 kWh |
| Equipment in source | One Smart 110 kWh PV-storage all-in-one unit |
| Grid-exchange requirement | Zero export, with local PV and battery supply prioritised |
Customer Situation and Energy Requirements
Office demand and PV output may overlap during working hours without matching throughout the day. Building services, occupancy and generation changes can still create surplus solar periods or peaks in grid import. The collection identifies high electricity expenditure and demand peaks as the commercial drivers.
The reference also lists dynamic capacity support. For a new building project, the relevant question is which peaks the battery can support, for how long, and with what reserve remaining. Battery support should be evaluated alongside the actual transformer and building-distribution limits.
Storage Integration and Control Strategy
The architecture combines PV, storage, the grid and loads on the site network. The desired operating priority avoids grid import when PV and available battery discharge can meet demand. A zero-export target governs the opposite power direction.
An EMS needs reliable site measurements to balance those objectives. It must respect the battery's available charge and discharge limits while coordinating any supported PV reduction. A full battery or a sudden reduction in building demand can change the available operating options.
For an office building, defining the load scope is also essential. Any proposed backup reserve should identify the circuits it serves and the intended interruption performance. The source does not provide an essential-load schedule or a tested transfer time for this installation.
Intended Operational Value
The intended operating value is better alignment between local solar generation and building demand, together with control of selected import peaks. An agreed SOC strategy can allocate storage between daily energy management and any specified continuity requirement.
The collection gives no before-and-after electricity bills, measured self-consumption improvement or verified connection-upgrade saving. These results require a building-specific model and acceptance criteria rather than a capacity-based assumption.
Planning a Comparable Installation
- Separate the building’s interval demand from total annual consumption.
- Record PV output and the import/export measurement boundary.
- Define the reserve available for demand peaks and any essential circuits.
- Test changes in occupancy load, full-battery operation and loss of site measurements.
Related YINTU Storage Options
For a new building assessment, review the 50 kW / 115.2 kWh air-cooled commercial cabinet. It is a current catalogue reference with different energy from the installation described here. The commercial battery project budget guide helps identify the metering, controls and electrical work needed alongside storage equipment.
How YINTU Supports a Comparable Project
YINTU is an energy storage solution provider working with manufacturing partners, including YOTAI. We support application assessment, equipment selection and technical coordination for customer-specific projects. This article presents a supplier reference. YINTU does not claim to have designed or installed the featured site.
For a new proposal, share building load profiles, PV details, connection limits and the circuits requiring operational reserve. The agreed technical scope defines equipment, interfaces and service responsibilities. The source's 110 kWh equipment family should not be treated as identical to a current catalogue product with a different rating.
Project Questions
Does zero export stop the building from using grid electricity?
The zero-export target concerns power sent to the utility. Grid import can still supply the building when local resources are insufficient or another operating priority requires it.
How is peak support sized for an office?
Use the measured peak magnitude and duration, then include usable energy, operating limits and reserve commitments. The 50 kW / 110 kWh source rating does not establish whole-building coverage.
Project facts and photograph: YOTAI overseas C&I case collection, September 2026, slide 9. The source describes the configuration, requirements and technical challenges. Application analysis is provided by YINTU. The collection does not supply metered performance results for this project.