Liquid Cooled Energy Storage Solutions 125 KW 261 KWh Integrated C&I Storage Cabinet

Brand Name:YINTU
Model Number:YT-C&I ESS-125kW/261kWh-CE
Minimum Order Quantity:1 unit
Price:Quotation on request
Payment Terms:T/T
Supply Ability:5 units
Product Details
Highlight:

Liquid Cooled Energy Storage Solutions

,

261 KWh Energy Storage Cabinet

,

Integrated C&I Storage Cabinet

Rated AC Power: 125 KW
Nominal Battery Energy: 261.248 KWh
Battery Chemistry: LFP
Cell Capacity: 314 Ah
Rated DC Voltage: 832 V
DC Voltage Range: 728–936 V
Charge/Discharge Rate: ≤0.5 CP
Rated AC Current: 180 A
Grid AC Voltage: 400 V ±10%
Frequency: 50 / 60 Hz
Cooling: Liquid + Air Cooling
Cabinet Protection: IP54
Battery Compartment: IP55
Corrosion Protection: C4
Max Parallel Expansion: 2.5 MW; Project Design
Communication: Ethernet / RS485
Dimensions W×D×H: 1400×1400×2200 Mm
Weight: 2500 +5% Kg; Datasheet
Installation: Outdoor
Solution Provider: YINTU
Product Description

COMMERCIAL & INDUSTRIAL ENERGY STORAGE SOLUTIONS

125 kW / 261 kWh Liquid-Cooled C&I Storage Cabinet - CE Version

A 125 kW AC storage cabinet with 261.248 kWh of nominal LFP battery energy for commercial and industrial energy management. This CE-version configuration is designed for projects that need a compact outdoor storage unit, liquid-cooled batteries and coordinated on-grid or off-grid operation.

Equipment Overview

The cabinet integrates five battery packs, PCS, BMS, EMS, liquid cooling and a control box. Its source configuration is YTDS5T261L-P0125S (Smart261L-CE). Solar integration in the concept shown below uses an external PV inverter on the AC bus; a direct PV DC input is not specified for this cabinet.

YINTU is an energy storage solution provider. We work with capable manufacturing partners to match equipment, system configuration and project services to each customer's commercial or industrial site.

YT-C&I ESS-125kW/261kWh-CE application concept
Illustrative application concept. Equipment and site layout depend on the project.

Commercial & Industrial Application Scenarios

Factories and industrial parks

Use scheduled charging and discharging to manage short demand peaks from production equipment and common services. YINTU starts with interval demand data, transformer limits and tariff periods to define an operating schedule and battery reserve. Savings depend on the site's actual load and tariff structure.

Commercial rooftop PV retrofits

Add storage alongside an existing PV inverter to move available daytime solar energy toward later consumption. The project design coordinates the PV inverter, metering and EMS, including any export limits. This AC-coupled arrangement is suitable for assessment where a working rooftop PV system is already installed.

Warehouses and cold-chain facilities

Plan storage around refrigeration cycles, loading equipment, lighting and other essential services. Separating priority loads helps set a realistic backup objective. Motor-starting demand and the required autonomy must be checked before confirming an off-grid configuration.

EV charging and logistics depots

Use the cabinet as part of a demand-management scheme when vehicle charging overlaps with site production or building demand. Charging schedules, connection capacity and available battery energy determine how much peak buffering is practical.

Staged storage expansion

The datasheet lists parallel expansion up to 2.5 MW. A multi-cabinet project requires a coordinated electrical layout, controls, protection and grid-interface review. VPP participation is assessed only where local rules, communications and commercial arrangements permit.

System Features and Project Value

Integrated cabinet architecture

Five LFP packs and the power-conversion, battery-management and energy-management functions are packaged in one cabinet, helping simplify equipment coordination for a site-specific solution.

Liquid cooling and outdoor protection

The source specifies intelligent battery liquid cooling, C4 corrosion protection, IP54 for the cabinet and IP55 for the battery compartment. These are distinct protection ratings and must be matched to the installation environment.

Efficient conversion and monitoring

The datasheet reports up to 99% SiC PCS conversion efficiency. This is a PCS value, not whole-system round-trip efficiency. Local operation, cloud/OTA capabilities and remote diagnostics are listed; project communications and access arrangements are confirmed separately.

Layered safety provisions

The datasheet describes dual monitoring, fault isolation and multiple venting/fire-protection measures. The final fire-protection arrangement, site emergency response and installation clearances are established in the approved equipment and project documents.

How the System Fits Your Site

The conceptual AC-coupled arrangement connects the storage cabinet, utility grid, external PV inverter and commercial loads through the site AC bus. The EMS coordinates the storage operating schedule. Backup or island operation requires suitable isolation, switching and protection; the drawing does not imply that an existing site is automatically ready for off-grid operation.

YT-C&I ESS-125kW/261kWh-CE conceptual system topology
Concept diagram only. Follow the approved single-line diagram and installation documents.

Technical Specifications

Battery and DC Parameters

Parameter Specification
Model YT-C&I ESS-125kW/261kWh-CE
Source configuration YTDS5T261L-P0125S (Smart261L-CE)
Battery chemistry / cell rating LFP; 3.2 V / 314 Ah
Nominal battery energy 261.248 kWh
Rated DC voltage 832 V
DC voltage range 728–936 V
Charge/discharge rate ≤0.5 CP
Battery cooling Intelligent liquid cooling

AC and Operating Modes

Parameter Specification
Rated AC power / current 125 kW / 180 A
Grid-connected AC voltage 400 V ±10%
Rated frequency 50 / 60 Hz
Frequency range 45–55 Hz / 55–65 Hz
Current distortion THDi <3% at rated power
Power factor >0.99 at rated power; adjustable from -1 (leading) to +1 (lagging)
Off-grid voltage / frequency 400 V ±5%; 50 / 60 Hz
Off-grid voltage distortion <3% with linear load
PCS conversion efficiency Up to 99%, as stated in the datasheet
Maximum parallel expansion 2.5 MW; subject to approved system architecture
Operating modes Grid-tied, off-grid and VPP; project conditions apply

Environment, Protection and Installation

Parameter Specification
Installation / system cooling Outdoor; liquid cooling + air cooling
Ingress protection IP54 cabinet; IP55 battery compartment
Corrosion protection C4
Fire protection Datasheet: Aerosol + water-based fire protection (optional); confirm final arrangement
Operating temperature -20°C to 45°C; datasheet notes derating above 45°C
Storage temperature -20°C to 35°C for ≤6 months; -20°C to 45°C for ≤1 month
Recommended storage SOC 20–50%
Humidity 0–95% RH, non-condensing
Altitude Within 4,000 m; derating above 2,000 m
Daily cycling limit Maximum 2 charges and 2 discharges per day
Dimensions (W × D × H) 1,400 × 1,400 × 2,200 mm
Weight 2,500 +5% kg, as written in the datasheet; confirm shipping weight

Controls and Datasheet Standards

Parameter Specification
Communication interfaces Ethernet / RS485
Protocols Modbus TCP / IEC 104 / Modbus RTU
Listed standards IEC 62619; IEC 60730; IEC 61000; IEC 62477; EN 50549
Listed grid references VDE 4105 / 4110 / 4120
Transport references UN38.3; UN3480 is a transport classification
Document scope CE Version is the product designation. Confirm certificates, test reports and applicable grid approvals for the ordered configuration.

From Site Requirements to a Storage Solution

1. Define the operating objective

Identify whether the priority is peak management, solar self-consumption, backup or microgrid operation. Use the actual load profile and generation resources to set the power, energy and operating reserve.

2. Match equipment and interfaces

YINTU coordinates equipment selection and technical clarification with the manufacturing partner, including voltage, controls, environment, expansion and optional functions.

3. Confirm delivery and service scope

The project quotation defines the cabinet configuration, external switchgear, protection and metering, PV equipment, generator interface, transport, commissioning support and after-sales responsibilities. External equipment and on-site works are included only when expressly specified. Warranty, lead time and commercial terms are confirmed in the agreed quotation.

Frequently Asked Questions

Can this cabinet take PV strings directly?

A direct PV DC input is not specified in this datasheet. The solution shown uses an external PV inverter connected to the site AC bus. PV-inverter compatibility and EMS coordination are reviewed for each project.

Does 261.248 kWh guarantee a fixed backup duration?

No. Runtime depends on actual load, allowed state-of-charge range, reserve settings, conversion losses, temperature and equipment limits. Power and energy must both be checked against the required duty.

Is the CE version already approved for every European site?

The datasheet lists standards and grid-code references. The applicable certificate scope, firmware, network settings and local utility requirements must be checked for the exact project and delivered configuration.

Is YINTU the cabinet manufacturer?

YINTU provides solution selection, project coordination and supply support through manufacturing partners. The final quotation identifies the equipment and service responsibilities.

Discuss Your C&I Energy Storage Project

Send YINTU your location, grid voltage and frequency, interval load data, peak demand, PV capacity, generator details, required backup loads and operating hours. We will coordinate equipment selection and a project-specific configuration for technical review.

Specifications are transcribed from the supplied YINTU datasheets and remain subject to the confirmed configuration and approved technical documents. Nominal battery energy is not usable AC energy. Application images and topology diagrams are illustrative concepts, not completed project references. Final installation, protection, source switching and grid approval must follow the site design.

You May Also Like
Quality Floor Standing Residential Energy Storage Systems 16 KWh Long Lasting Home Energy Solutions factory

Floor Standing Residential Energy Storage Systems 16 KWh Long Lasting Home Energy Solutions

A 16 kWh floor-standing LiFePO4 battery with 51.2 V, 314 Ah and four casters. Standard current: 100 A; maximum continuous current: 200 A. Supports up to 15 parallel units, Bluetooth and BMS communication with a compatible external inverter.
Quality Indoor Floor Standing Residential Energy Storage Systems All In One Solar Storage For Homes factory

Indoor Floor Standing Residential Energy Storage Systems All In One Solar Storage For Homes

Floor-standing home solar storage with an integrated off-grid PV inverter and LiFePO4 battery. Four configurations offer 5.12–14.3 kWh and 5–11 kW, with direct PV input, AC charging and 230 V output. IP20 for indoor use.
Quality 12 KW / 32 KWh Stackable Home Solar Energy Storage Systems All In One ESS IP20 factory

12 KW / 32 KWh Stackable Home Solar Energy Storage Systems All In One ESS IP20

A 32 kWh stackable home ESS using 2 × 16 kWh battery modules and a 12 kW split-phase inverter. The appliance-style design combines solar input and battery storage for compatible 120 / 240 V homes.
Quality 5 KW 10.24 KWh Stackable Residential Battery Storage Systems All In One Solar ESS factory

5 KW 10.24 KWh Stackable Residential Battery Storage Systems All In One Solar ESS

A 10.24 kWh stackable home battery with an integrated 5 kW inverter, 120 V AC output and up to 6 kW PV input. The appliance-style enclosure brings solar charging and battery storage into a tidy indoor system.
Contact Us
You Can Contact Us At Anytime!