3290 kWh Utility Scale Battery Energy Storage Systems Modular 20 Foot Battery Container
20 ft Modular Utility Scale BESS
,3290 kWh Utility Scale Battery Energy Storage Systems
,IP54 Grid Support Utility ESS
UTILITY-SCALE DC BATTERY STORAGE
3290 kWh Air-Cooled DC Battery Container for Utility Storage
A 20 ft battery block for renewable energy shifting and grid dispatch, combining 3290.11 kWh of LFP battery energy with controlled air cooling. Its 20 ft format provides a defined battery building block for a multi-container project. The number of blocks and PCS power can be selected separately around the required dispatch duration.
Equipment and Supply Scope
This listing covers the DC-side battery container, including LFP batteries, battery management, thermal management, DC distribution and the specified protection systems. It is not a complete AC-connected power station. PCS, plant EMS/PPC, transformers, switchgear and grid connection equipment are separate project items unless expressly included in the agreed supply scope.
YINTU is an energy storage solution provider. We work with manufacturing partners to select battery equipment and coordinate the interfaces required for each project.
Grid and Renewable Energy Applications
Large solar farms: move energy into the dispatch window
Charge the battery through the selected conversion system when solar production exceeds the desired export schedule. Discharge later through the PCS to support evening delivery. Available charging headroom, export limits and the solar profile determine how much curtailed energy can actually be recovered.
Renewable output smoothing and dispatch control
A coordinated PCS and plant EMS can charge or discharge the battery to moderate short-term variations in photovoltaic or wind output and follow an export schedule. The achievable ramp rate and response depend on converter capability, communications, available state of charge and the grid operator’s requirements.
Frequency regulation and operating reserves
The battery supplies or absorbs active energy when the selected PCS and controller respond to a regulation signal. Reserve availability must respect battery voltage, temperature, charge/discharge limits and state of charge. Frequency response is a complete-system function, not a standalone guarantee from the battery enclosure.
Peak management at a grid connection
Discharging during defined high-load intervals can reduce the peak power requested from a connection or support a constrained node. Suitability depends on the local load profile, connection limit and required duration. Any infrastructure-deferral or revenue case needs a project study; the battery rating alone does not establish the result.
System Features and Project Value
A defined energy block for plant design
Its 20 ft format provides a defined battery building block for a multi-container project. The number of blocks and PCS power can be selected separately around the required dispatch duration.
Controlled airflow across battery packs
Tree-inspired airflow channels and pack-level fan-speed control are described in the datasheet, with system temperature difference at or below 5°C. Coordinated cooling helps manage thermal conditions during the planned duty cycle. Ambient temperature and cooling auxiliary consumption must be included in the plant energy model.
Layered monitoring and protection
The three-level BMS works with DC collection, grounding and protection systems. Pack-targeted suppression, combustible-gas detection, smoke prevention and explosion venting are described alongside 5VA insulation materials. Final fire-system selection and site fire design require configuration-specific review.
Service life planned around real duty
The source states a 20-year design life and up to two charges and two discharges per day. These are design references, not a warranty or a promise of constant lifetime capacity. Dispatch depth, ambient conditions, maintenance and end-of-life capacity targets need to be agreed for the project.
How the System Fits Your Site
In the illustrated AC-coupled example, the battery DC output connects to a compatible bidirectional PCS, then through the project transformer and switchgear to the grid. A photovoltaic plant connects through its own inverter and interface equipment to the AC collector. Plant EMS/PPC coordinates dispatch and exchanges status with the BMS. This battery container does not connect directly to PV strings or the AC grid. Alternative architectures require an approved project design.
Technical Specifications
Battery and DC Ratings
| Parameter | Specification |
|---|---|
| Model | YT-Utility ESS-3290kWh |
| Cell chemistry / specification | LFP / 3.2 V / 280 Ah |
| Rated battery energy | 3290.11 kWh |
| Nominal DC voltage | 1305.6 V |
| Battery voltage range | 1142–1468.8 V |
| Charge / discharge rate | ≤0.5 CP |
| System voltage class | 1500 V |
| AC output power | Not specified; determined by separately selected PCS and system design |
| Design life | 20 years (source design reference; not warranty) |
Thermal Management and Protection
| Parameter | Specification |
|---|---|
| Cooling method / medium | Air cooling; pack-level fan-speed control |
| Temperature difference | ≤5°C (system) |
| BMS architecture | 3-level |
| Auxiliary power supply | 25 kW; 380 V & 480 V / 50 Hz (source notation; confirm selection) |
| Fire suppression | S-type aerosol / HFC-227EA / perfluorohexanone options |
| Ingress protection | IP54 |
| Corrosion protection | C3; C4 / C5 optional |
Environment and Enclosure
| Parameter | Specification |
|---|---|
| System operating temperature | −30 to +50°C; derating above 45°C |
| Operating humidity | 0–95% RH; non-condensing |
| Altitude | ≤3000 m |
| Installation | Outdoor |
| Daily duty | Up to 2 charges and 2 discharges per day |
| Dimensions (W × D × H) | 6058 × 2438 × 2896 mm (20 ft) |
| Approximate weight | 33 t |
Interfaces and Project Scope
| Parameter | Specification |
|---|---|
| Communication interfaces | Ethernet |
| External communication protocol | Modbus TCP |
| PCS and AC grid connection | Separately specified project equipment |
| Plant EMS / PPC | Project-level control scope to be confirmed |
| Standards listed in source | GB/T 36276; GB/T 34131; UL 1973; UL 9540A; IEC 62619; UN38.3 |
Auxiliary AC supply ratings describe internal service power, not AC export capability. “CP” is the source rate notation retained without reinterpretation. Nameplate battery energy is not guaranteed usable AC energy. Standards are source references; confirm certificates and test-report scope for the supplied configuration.
From Project Requirements to a Storage Plant
1. Define power, energy and dispatch
Use generation and grid-dispatch profiles to define AC power, usable energy, delivery duration and reserve commitments. Evaluate auxiliary demand, conversion losses, temperature derating and the agreed end-of-life capacity target.
2. Match equipment and site design
YINTU coordinates battery and PCS interface reviews with manufacturing partners. Check the full DC voltage window, communications, grid requirements, foundations, lifting access, corrosion conditions and maintenance clearances.
3. Confirm the project scope
Confirm the battery supply boundary, external PCS, plant EMS/PPC, transformer, switchgear, protection, auxiliary power, civil works, fire design and commissioning responsibilities. Grid connection and local approvals are project-specific.
Frequently Asked Questions
Does this product include a grid-connected inverter?
The published scope is the DC battery container. A compatible PCS and the required AC/MV interface are specified separately. The auxiliary AC supply does not make the container a standalone grid-connected system.
Can solar panels connect directly to the battery container?
No direct PV-string interface is offered in this listing. Solar integration requires the appropriate PV inverter or DC conversion architecture, protection and plant controls. The illustrated scheme is one possible AC-coupled arrangement.
How many containers and how much PCS power are needed?
Start with the required AC MW, usable MWh, dispatch duration and end-of-life target. Account for the usable SOC window, conversion losses, auxiliary demand, temperature derating and reserve commitments. Select the converter against the entire battery voltage window and the agreed charge/discharge limits.
Can it provide backup, grid-forming or black-start operation?
These functions require a specifically engineered complete system, including suitable PCS controls, auxiliary-power arrangements, protection and an approved operating sequence. They are not standalone capabilities guaranteed by this DC battery container.
Plan Your Utility-Scale Battery Storage Project
Share the required AC power and usable energy, solar generation profile, grid connection voltage, dispatch schedule, site climate and available layout. YINTU can coordinate battery selection, PCS matching and technical clarification with manufacturing partners for a defined project scope.
Parameters are based on the supplied model datasheet and remain subject to final technical confirmation. Illustrations show application concepts, not completed YINTU projects. Listed standards require configuration-specific documentation; cycle life and design life are not warranty commitments.