5017 KWh Utility Scale Energy Storage Systems Liquid Cooled For Large Solar Storage Projects
5017 KWh Utility Scale Energy Storage Systems
,Liquid Cooled LFP Utility BESS
,30 ft Utility Scale Battery Container
UTILITY-SCALE DC BATTERY STORAGE
5017 kWh Liquid-Cooled DC Battery Container for Large Solar Projects
A 5017.6 kWh LFP battery container in a 30 ft format, designed as a DC energy block for large renewable generation and grid storage plants. The non-walk-in layout provides external maintenance access while cluster management and liquid cooling support multi-megawatt-hour operation. Nominal DC voltage and the final series arrangement must be confirmed before PCS selection.
Equipment and Supply Scope
This listing covers the DC-side battery container, including LFP batteries, battery management, thermal management, DC distribution and the specified protection systems. It is not a complete AC-connected power station. PCS, plant EMS/PPC, transformers, switchgear and grid connection equipment are separate project items unless expressly included in the agreed supply scope.
YINTU is an energy storage solution provider. We work with manufacturing partners to select battery equipment and coordinate the interfaces required for each project.
Grid and Renewable Energy Applications
Large solar plants: schedule energy beyond daylight hours
The 5017.6 kWh battery block can form part of a solar-plus-storage plant that shifts daytime generation to later delivery periods. Plant-level power conversion, dispatch controls and interconnection equipment are specified separately. Final PCS compatibility requires confirmation of nominal DC voltage and the complete battery operating window.
Renewable output smoothing and dispatch control
A coordinated PCS and plant EMS can charge or discharge the battery to moderate short-term variations in photovoltaic or wind output and follow an export schedule. The achievable ramp rate and response depend on converter capability, communications, available state of charge and the grid operator’s requirements.
Frequency regulation and operating reserves
The battery supplies or absorbs active energy when the selected PCS and controller respond to a regulation signal. Reserve availability must respect battery voltage, temperature, charge/discharge limits and state of charge. Frequency response is a complete-system function, not a standalone guarantee from the battery enclosure.
Peak management at a grid connection
Discharging during defined high-load intervals can reduce the peak power requested from a connection or support a constrained node. Suitability depends on the local load profile, connection limit and required duration. Any infrastructure-deferral or revenue case needs a project study; the battery rating alone does not establish the result.
System Features and Project Value
A defined energy block for plant design
The non-walk-in layout provides external maintenance access while cluster management and liquid cooling support multi-megawatt-hour operation. Nominal DC voltage and the final series arrangement must be confirmed before PCS selection.
Liquid cooling for thermal consistency
Water-and-glycol cooling is specified with a temperature difference of ≤3°C. Online leak detection and cluster-level control support monitoring of the cooling and battery systems. Thermal performance contributes to consistent operation; it does not eliminate degradation or replace operating limits.
Layered electrical and fire protection
The source describes online insulation monitoring, four-level circuit-breaker protection and pack-level combustible-gas detection linked to BMS/EMS. Targeted suppression and the selected fire system support fault response. Final equipment, water interfaces and fire strategy are confirmed with the manufacturing partner and site designers.
Maintainability and operating visibility
Each cluster has a dedicated sub-controller for charge/discharge management and balancing. Cloud monitoring is described in the source; connectivity and service scope are confirmed per project. The non-walk-in enclosure allows external maintenance. Monitoring supports inspection and planning but is not a guarantee of uninterrupted availability.
How the System Fits Your Site
In the illustrated AC-coupled example, the battery DC output connects to a compatible bidirectional PCS, then through the project transformer and switchgear to the grid. A photovoltaic plant connects through its own inverter and interface equipment to the AC collector. Plant EMS/PPC coordinates dispatch and exchanges status with the BMS. This battery container does not connect directly to PV strings or the AC grid. Alternative architectures require an approved project design.
Technical Specifications
Battery and DC Ratings
| Parameter | Specification |
|---|---|
| Model | YT-Utility ESS-5017kWh |
| Cell chemistry / specification | LFP / 3.2 V / 280 Ah |
| Rated battery energy | 5017.6 kWh; P2 at 25 ±3°C |
| Nominal DC voltage | To be confirmed |
| Battery voltage range | 1120–1440 V |
| Charge / discharge rate | ≤0.5 CP |
| Source maximum charge / discharge power | 2500 kW; configuration reference, not guaranteed AC export |
| Battery charging temperature | 0 to +50°C |
| Battery discharging temperature | −20 to +55°C |
| Recommended ambient temperature | 25 ±10°C |
| Cycle life | ≥6000 cycles; 25 ±10°C; P2; 90% DOD; 80% EOL |
Thermal Management and Protection
| Parameter | Specification |
|---|---|
| Cooling method / medium | Liquid cooling / water + glycol |
| Temperature difference | ≤3°C |
| BMS architecture | 3-level |
| Auxiliary power supply | Approx. 36 kW; 400 V / 50 Hz; 3N + PE |
| Fire suppression | Perfluorohexanone + water; S-type aerosol / HFC-227EA optional |
| Ingress protection | IP55 |
| Corrosion protection | C3; C4 / C5 optional |
| Lightning protection | Level II |
Environment and Enclosure
| Parameter | Specification |
|---|---|
| System operating temperature | −20 to +50°C; derating above 45°C |
| Storage conditions | −20 to +45°C; less than 6 months |
| Operating humidity | 0–95% RH; non-condensing |
| Altitude | ≤3000 m |
| Installation | Outdoor; non-walk-in external maintenance |
| Daily duty | Up to 2 charges and 2 discharges per day |
| Dimensions (W × D × H) | 9125 × 2438 × 2896 mm (30 ft) |
| Approximate weight | 47 t |
Interfaces and Project Scope
| Parameter | Specification |
|---|---|
| Communication interfaces | CAN / Ethernet / RS485 |
| External communication protocol | Modbus TCP |
| PCS and AC grid connection | Separately specified project equipment |
| Plant EMS / PPC | Project-level control scope to be confirmed |
| Standards listed in source | GB/T 36276; GB/T 34131; UL 1973; UL 9540A; IEC 62619; UN38.3 |
Auxiliary AC supply ratings describe internal service power, not AC export capability. “CP” and “P2” are source designations retained without reinterpretation. Nameplate battery energy is not guaranteed usable AC energy. Standards are source references; confirm certificates and test-report scope for the supplied configuration. Nominal DC voltage and the final pack/series arrangement are pending confirmation. Do not use the erroneous nominal-voltage entry from the source as a design value.
From Project Requirements to a Storage Plant
1. Define power, energy and dispatch
Use generation and grid-dispatch profiles to define AC power, usable energy, delivery duration and reserve commitments. Evaluate auxiliary demand, conversion losses, temperature derating and the agreed end-of-life capacity target.
2. Match equipment and site design
YINTU coordinates battery and PCS interface reviews with manufacturing partners. Check the full DC voltage window, communications, grid requirements, foundations, lifting access, corrosion conditions and maintenance clearances.
3. Confirm the project scope
Confirm the battery supply boundary, external PCS, plant EMS/PPC, transformer, switchgear, protection, auxiliary power, civil works, fire design and commissioning responsibilities. Grid connection and local approvals are project-specific.
Frequently Asked Questions
Does this product include a grid-connected inverter?
The published scope is the DC battery container. A compatible PCS and the required AC/MV interface are specified separately. The auxiliary AC supply does not make the container a standalone grid-connected system.
Can solar panels connect directly to the battery container?
No direct PV-string interface is offered in this listing. Solar integration requires the appropriate PV inverter or DC conversion architecture, protection and plant controls. The illustrated scheme is one possible AC-coupled arrangement.
How many containers and how much PCS power are needed?
Start with the required AC MW, usable MWh, dispatch duration and end-of-life target. Account for the usable SOC window, conversion losses, auxiliary demand, temperature derating and reserve commitments. Select the converter against the entire battery voltage window and the agreed charge/discharge limits.
Can it provide backup, grid-forming or black-start operation?
These functions require a specifically engineered complete system, including suitable PCS controls, auxiliary-power arrangements, protection and an approved operating sequence. They are not standalone capabilities guaranteed by this DC battery container.
Which voltage must be clarified before ordering?
Nominal DC voltage and the final series arrangement remain to be confirmed with the manufacturing partner. The supplied datasheet lists a battery voltage range of 1120–1440 V. Complete the voltage and PCS-interface review before approving the design.
Plan Your Utility-Scale Battery Storage Project
Share the required AC power and usable energy, solar generation profile, grid connection voltage, dispatch schedule, site climate and available layout. YINTU can coordinate battery selection, PCS matching and technical clarification with manufacturing partners for a defined project scope.
Parameters are based on the supplied model datasheet and remain subject to final technical confirmation. Illustrations show application concepts, not completed YINTU projects. Listed standards require configuration-specific documentation; cycle life and design life are not warranty commitments.