Multi Slot Battery Swapping Cabinet Smart Charging Remote Monitoring for Delivery Riders

Brand Name:YINTU
Model Number:YT-Swap-AI Series
Price:Project-specific quotation
Product Details
Highlight:

Multi Slot Battery Swapping Cabinet

,

Battery Swapping Cabinet for Delivery Rider

,

7 Inch Touchscreen Battery Swapping Cabinet

Product Type: Battery Swapping Cabinet For Light Electric Mobility
Series: YT-Swap-AI Series
Bay Options: 8 / 12; Model-dependent
Detailed Rating Coverage: AI-6008-1 And AI-6012-1 Only
Rated Cabinet Input: 100-240 Vac; Documented Models
Frequency: 50 Hz; Documented Models
Per-Bay Input Voltage: 176-264 Vac; Documented Models
Per-Bay Output Voltage: 40-72 V; Documented Models
Per-Bay Output Current: 1-10 A; Documented Models
Per-Bay Rated Power: 500 W; Documented Models
Display: 7-inch Capacitive Touchscreen; Documented Models
Controller: Android / 2 GB RAM; Documented Models
rs232 Ports: 4 Channels; Documented Models
User Access: Scan-based Service; Platform Configuration Applies
Battery Compatibility: Dimensions / Connector / Charging Profile / BMS Matching
Network Options: Cellular / CAN / RS485 / Bluetooth; Controller-dependent
Protection Options: Smoke / Liquid / Temperature Sensing; Selected Configuration
Service Options: Rental And Platform Integration Per Project
Application: Delivery Fleets / Communities / Campuses / Rental Networks
Solution Provider: YINTU
Product Description

SMART BATTERY SWAPPING SOLUTIONS

AI Series 8- and 12-Bay Battery Swapping Cabinets for Delivery Riders

AI Series 8- and 12-bay battery swapping cabinets for delivery riders, communities and campuses, with scan-to-swap operation and battery identification. Detailed 500 W charging specifications apply to AI-6008-1 and AI-6012-1.

Product Overview

The AI Series provides a compact service point for exchanging compatible light-electric-vehicle batteries. Operators can choose an eight- or twelve-bay configuration to suit local rider demand, available space and the planned battery inventory. Mini-program scan operation and battery identification bring a managed exchange process to locations that riders already visit.

YINTU is a solution provider. We work with capable manufacturing partners to match cabinet hardware, compatible batteries and service-platform requirements for each operator. Equipment, battery supply, software, payment services and local support are defined in the project proposal.

AI Series battery swapping applications
Application concept using the datasheet product illustration. Illustrated cabinet: AI-6012-1. Appearance and equipment vary by model.

Key Features

Scan-to-swap access for everyday rider routes

Battery identification helps the operator associate each exchange with the supported battery and service workflow. The datasheet states a 10-second swap time; actual completion depends on user handling, platform response and battery availability.

Choose the compartment that fits the battery

The documented AI-6008-1 and AI-6012-1 models use different compartment dimensions. This makes physical battery matching an early selection step, alongside the connector, charging profile and BMS protocol. An additional AI-6008-2 eight-bay variant is listed for project selection.

Managed charging and operator access

The documented configuration combines per-bay charging with an Android controller, 2 GB RAM and a 7-inch capacitive touchscreen. These components support the selected cabinet interface and service workflow. Charging settings must match the approved battery; output voltage, current and power limits apply together.

Protection, sensing and maintenance options

Project options include smoke, liquid and temperature sensing, battery-in-position and maintenance-door detection, electronic locks with feedback, status lights and abnormal-condition shutdown. Fan and heater control can be specified with the selected controller. The series describes individual-bay fire-control functions; the exact protection arrangement is selected for the project.

Connectivity and service customization

CAN / RS485, cellular connectivity, Bluetooth and remote OTA upgrades are listed as controller-dependent integration options. GPS + GPRS battery-tracking functionality is a system option. Confirm battery-side tracking hardware, network availability, service access and fees when defining the proposal.

Applications and Operator Value

Delivery rider hubs

Place battery exchange near dispatch counters, restaurants or rider rest areas. A stock of compatible charged batteries can reduce the need to wait through a full charging cycle. Size the cabinet and spare-battery pool around peak dispatch periods and return patterns.

Community parking and commuting routes

Provide a familiar exchange location near recurring rider demand. Defined access permissions, service hours and local maintenance responsibilities help the property manager and operator run the site consistently.

Campuses and business parks

Support approved electric two-wheelers and mopeds at designated parking areas. Match the battery fleet before deployment and coordinate traffic flow, service access and power supply with the site operator.

Managed local service points

Add battery exchange to an established mobility or maintenance outlet. Staff can support first-time users, inspect returned batteries and escalate abnormal conditions through the agreed operating process.

Battery Exchange and Platform Concept

A typical service flow starts with user identification or a mini-program scan. The operator platform authorizes the transaction; the cabinet identifies and accepts a compatible returned battery, then releases an available approved battery through the configured workflow. Returned batteries enter managed charging, while cabinet status and faults are shared with the selected service platform.

AI Series battery exchange and platform concept
Functional concept only. Exchange sequence, connectivity, payment integration and safety controls follow the approved configuration.

Model Selection

Model Bays Cabinet size (mm, excluding canopy) Compartment size (mm) Parameter coverage
YT-Swap-AI-6008-1 8 798 × 600 × 1706 124 × 179 × 377 Detailed ratings below
YT-Swap-AI-6008-2 8 To be confirmed To be confirmed Variant-specific ratings to be confirmed
YT-Swap-AI-6012-1 12 1102 × 600 × 1908 190 × 190 × 383 Detailed ratings below

Dimensions follow the order printed in the datasheet; axes are not identified. Confirm the final installation drawing, canopy dimensions, access clearance and compatible battery envelope before selecting a location. The product photo illustrates AI-6012-1 and does not establish the dimensions or ratings of other variants.

Electrical and Controller Specifications

The following ratings apply to AI-6008-1 and AI-6012-1. Other listed variants require their own confirmed specifications.

Parameter Specification
Applicable models AI-6008-1 and AI-6012-1
Rated cabinet input voltage 100-240 Vac
Frequency 50 Hz
Input voltage per compartment 176-264 Vac
Output voltage per compartment 40-72 V
Input current per compartment To be confirmed
Output current per compartment 1-10 A
Rated power per compartment 500 W
Operating system Android
RAM 2 GB
Display 7-inch capacitive touchscreen
RS232 serial ports 4 channels
Additional serial support TTL; 1 × R485 (source designation; interface to be confirmed)
Other interfaces Audio, power amplifier, HDMI, LVDS

Configuration notes: The datasheet lists 100-240 Vac at cabinet level and 176-264 Vac per compartment. Confirm the actual charger input arrangement and approved site supply. Total cabinet input power and simultaneous charging capacity are not specified; do not calculate feeder sizing solely by multiplying bay count by 500 W. The source marks the per-bay input current as unconfirmed because its original unit is invalid. The additional serial designation “R485” also requires confirmation.

Project Selection and Deployment

Match the battery fleet

Provide battery dimensions, mass, connector layout, chemistry, charging limits and BMS protocol. Confirm compatibility through the agreed technical review and sample verification.

Size the operating service

Define expected daily exchanges, peak arrival periods, charged-battery availability and the spare-battery pool. Bay count alone does not determine swaps per day or charging throughput.

Confirm the installation site

Check electrical supply, protection, earthing, installation clearances and access for maintenance. The sheets do not provide an IP rating or operating-temperature range; confirm suitability for the planned site. A canopy alone does not establish unrestricted outdoor use.

Agree the software and support scope

Specify operator access, user language, payment provider, connectivity, remote updates, subscription or rental workflow and local service responsibilities. Confirm which hardware, batteries, software services and commissioning activities are included.

Frequently Asked Questions

Can these cabinets work with any electric two-wheeler battery?

Compatibility is project-specific. Physical dimensions, connector, charge profile, voltage limits and BMS communication must all match. A battery fitting inside the compartment is not sufficient on its own.

Are batteries and platform services included?

The datasheets describe cabinet and service capabilities, not a fixed supply bundle. YINTU confirms cabinet hardware, battery quantities, platform access, payment integration and service coverage in the quotation.

Does every model use a 500 W charger and the same controller?

No. The detailed ratings shown here apply only to AI-6008-1 and AI-6012-1. Other variants and charging options require separate confirmation.

Can the system be customized for our rental network?

YINTU coordinates the selected cabinet appearance, battery interface and service-platform requirements with manufacturing partners. Final features, software compatibility and delivery scope are agreed before order confirmation.

Plan Your Battery Swapping Network

Send YINTU your target market, battery specifications, preferred bay count, site power and expected exchange demand. We will coordinate a suitable cabinet configuration and a clear equipment and service proposal for your operation.

Technical reference: supplied YT-Swap-AI Series datasheet, V1.0, October 2026. Series illustrations; final appearance and specifications follow the approved model configuration. Original datasheet attached.

You May Also Like
Quality Floor Standing Residential Energy Storage Systems 16 KWh Long Lasting Home Energy Solutions factory

Floor Standing Residential Energy Storage Systems 16 KWh Long Lasting Home Energy Solutions

A 16 kWh floor-standing LiFePO4 battery with 51.2 V, 314 Ah and four casters. Standard current: 100 A; maximum continuous current: 200 A. Supports up to 15 parallel units, Bluetooth and BMS communication with a compatible external inverter.
Quality Indoor Floor Standing Residential Energy Storage Systems All In One Solar Storage For Homes factory

Indoor Floor Standing Residential Energy Storage Systems All In One Solar Storage For Homes

Floor-standing home solar storage with an integrated off-grid PV inverter and LiFePO4 battery. Four configurations offer 5.12–14.3 kWh and 5–11 kW, with direct PV input, AC charging and 230 V output. IP20 for indoor use.
Quality 12 KW / 32 KWh Stackable Home Solar Energy Storage Systems All In One ESS IP20 factory

12 KW / 32 KWh Stackable Home Solar Energy Storage Systems All In One ESS IP20

A 32 kWh stackable home ESS using 2 × 16 kWh battery modules and a 12 kW split-phase inverter. The appliance-style design combines solar input and battery storage for compatible 120 / 240 V homes.
Quality 5 KW 10.24 KWh Stackable Residential Battery Storage Systems All In One Solar ESS factory

5 KW 10.24 KWh Stackable Residential Battery Storage Systems All In One Solar ESS

A 10.24 kWh stackable home battery with an integrated 5 kW inverter, 120 V AC output and up to 6 kW PV input. The appliance-style enclosure brings solar charging and battery storage into a tidy indoor system.
Contact Us
You Can Contact Us At Anytime!