125 kW Liquid-Cooled ESS for Outdoor Retrofit Layouts
125 kW liquid-cooled ESS
,outdoor retrofit ESS layout
,commercial industrial energy storage
125 kW Liquid-Cooled ESS for Outdoor Retrofit Layouts
Plan a 125 kW, 261.248 kWh liquid-cooled cabinet in an existing outdoor plant area. Check its service envelope, AC tie-in, access route and communications before fixing the equipment layout.
YT-C&I ESS-125kW/261kWh-CE
Selected configuration
| Rated grid-connected power | 125 kW / 180 A |
|---|---|
| Rated battery energy | 261.248 kWh |
| DC nominal / operating range | 832 V / 728–936 V |
| Grid interface | 400 V ±10%, 50/60 Hz |
| Enclosure | IP54 cabinet, IP55 battery compartment, C4 corrosion protection |
| Dimensions (W × D × H) | 1400 × 1400 × 2200 mm |
| Approximate mass | 2500 kg, confirm transport mass with the final configuration |
| Communications | Ethernet / RS485 with Modbus TCP, IEC104 or Modbus RTU |
Survey the retrofit bay
Use the 1400 × 1400 mm cabinet footprint as the starting outline. Overlay the manufacturer’s door swing, cable entry and removal route on the existing plant drawing. Identify the route from unloading to foundation and the path a service technician would use with the cabinet doors open. The approximately 2500 kg equipment mass is a starting point for logistics and pad review. Obtain the final general arrangement and verified shipping data before freezing anchors or lifting plans.
Check the 400 V connection
The integrated cabinet combines the battery packs, PCS, BMS, EMS and thermal equipment. Its grid-connected rating is 125 kW and 180 A at the stated 400 V interface. Check existing switchboard capacity, spare breaker position, earthing and meter placement before ordering. For a retrofit behind a site transformer, agree which loads and generation the meter sees so the plant controls can act on the intended import or export point.
Reserve access for inspection and service
Use the outdoor IP54 cabinet rating and C4 corrosion reference to screen the intended environment. Confirm drainage, equipment clearances and ventilation with the manufacturer’s arrangement. The sheet identifies IP55 for the battery compartment and derating above 45°C. Record the intended access zones and the operator responsible for service isolation. The corrosion class and temperature reference inform placement alongside the actual site conditions.
Define equipment and site responsibilities
YINTU is an energy storage solution provider. We coordinate the cabinet and its connection requirements with the manufacturing partner. The project team specifies the feeder, protection, metering, foundation and site EMS interface. Exchange the register list and agreed alarm points before integration. Confirm backup and switching arrangements separately for the selected site topology.
Datasheet model YTDS5T261L-P0125S is the source reference. Cover is an illustrative view based on the existing model image.