16 kWh Floor-Standing Battery for Low-Voltage Inverter Matching
16 kWh floor-standing battery
,low-voltage inverter matching battery
,residential energy storage system
16 kWh Floor-Standing Battery for Low-Voltage Inverter Matching
Match a 51.2 V, 314 Ah floor-standing LFP battery with a compatible external inverter. Review the 40–58.4 V operating range, BMS profile and 120 kg equipment placement.
YT-Standing ESS-16kWh
Selected configuration
| Original model reference | YH-ESS-B314S16-F |
|---|---|
| Rated battery energy | 16 kWh |
| Nominal voltage / capacity | 51.2 V / 314 Ah |
| Operating voltage | 40–58.4 V |
| Standard / max. continuous current | 100 A / 200 A, charge and discharge |
| Communication | RS485 / RS232 / CAN / dry contact, Bluetooth |
| Dimensions (W × D × H) | 270 × 550 × 728 mm, source order |
| Net weight / installation | 120 kg, floor-standing with four caster wheels |
Choose the battery and inverter together
Start with the inverter’s supported battery voltage and compatible BMS profile. The YT-Standing ESS-16kWh is rated at 51.2 V and operates within the stated 40–58.4 V range. Ask for confirmation of the exact inverter model, firmware and communications settings. The availability of CAN or RS485 identifies an interface. Confirm the protocol and cable mapping with both equipment suppliers before final selection.
Size current against the load profile
The source lists 100 A standard charge and discharge current and 200 A maximum continuous current. At nominal voltage, 100 A corresponds to about 5.12 kW of battery DC power before conversion losses. Review the battery and inverter limits across the operating voltage range and expected temperature. Choose reserve settings, inverter charge current and expected load duty together. Where more capacity is required, confirm the approved parallel layout, BMS master arrangement and protective equipment.
Prepare the floor position and route
Review the 120 kg equipment mass, delivery path, available floor space and access to the right-side interfaces in the general arrangement. The four casters aid positioning within an approved handling plan. Agree the final restraint and service access with the installer. Check charging conditions against the source range of 0 to +55°C and confirm the installation environment for the exact model.
Define the residential supply scope
YINTU coordinates battery selection and compatibility review with manufacturing partners. The equipment in this listing is the DC battery. The external hybrid inverter, PV array, DC protection, AC distribution and backup circuits are specified separately. Share the inverter reference and the intended loads so the battery profile and installation arrangement can be checked before ordering.
Illustrative view of the existing model. Confirm inverter firmware and the approved installation arrangement.
Floor Standing Residential Energy Storage Systems 16 KWh Long Lasting Home Energy Solutions
Indoor Floor Standing Residential Energy Storage Systems All In One Solar Storage For Homes
12 KW / 32 KWh Stackable Home Solar Energy Storage Systems All In One ESS IP20