20-Foot 5.016 MWh DC Battery Container for Service-Aisle Layouts

Brand Name:YINTU
Model Number:YT-Utility ESS-5015kWh
Product Details
Highlight:

20-foot 5.016 MWh battery container

,

DC battery container service-aisle layout

,

utility scale battery energy storage

Rated DC Battery Energy: 5015.96 KWh
Cell Chemistry / Capacity: LFP, 314 Ah
Nominal DC Voltage / Window: 1331.2 V / 1164.8–1497.6 V
Container Dimensions: 6058 × 2438 × 2896 Mm, 20 Ft High Cube
Approximate Mass: 41 T
Cooling / Enclosure: Water-glycol Liquid Cooling, IP55
Auxiliary Supply: Approx. 40 KW, 400 V / 50 Hz, 3N + PE
Maintenance / Communications: Outdoor External Maintenance, Modbus TCP Over Agreed Interfaces
Product Description

20-Foot 5.016 MWh DC Battery Container for Service-Aisle Layouts

Plan a 5,015.96 kWh non-walk-in battery container around external service access. Check cable routes, liquid-cooling service zones and the separately selected PCS and plant controls.

YT-Utility ESS-5015kWh

Selected configuration

Rated DC battery energy 5015.96 kWh
Cell chemistry / capacity LFP, 314 Ah
Nominal DC voltage / window 1331.2 V / 1164.8–1497.6 V
Container dimensions 6058 × 2438 × 2896 mm, 20 ft high cube
Approximate mass 41 t
Cooling / enclosure Water-glycol liquid cooling, IP55
Auxiliary supply Approx. 40 kW, 400 V / 50 Hz, 3N + PE
Maintenance / communications Outdoor external maintenance, Modbus TCP over agreed interfaces

Draw the service aisle before setting row spacing

The Aurora 5015 is a non-walk-in 20-foot high-cube DC battery block. Its 6058 × 2438 × 2896 mm enclosure is one part of the installed envelope. Use the manufacturer’s arrangement to identify the external door and panel openings, required removal space and liquid-cooling service points. Reserve a clear route for maintenance handling and emergency access. Coordinate the row orientation and spacing with civil and site protection requirements.

Separate the cable, service and lifting paths

Map the DC cable routing from the container to the selected PCS and coordinate crossing points with service access, barriers and drainage. Use the approximately 41 t source mass for preliminary logistics screening and obtain the verified shipping and lifting data for the ordered unit. Confirm the foundation and equipment clearance requirements from the approved drawings before placing multiple blocks.

Set the site integration and service responsibilities

The DC operating range is 1164.8–1497.6 V. Review the PCS voltage window, battery current limits, control handshake, fault isolation and maintenance procedures for the proposed arrangement. Agree the BMS data exchange with the plant EMS. The source lists an approximate 40 kW auxiliary supply at 400 V, 50 Hz. Confirm the selected auxiliaries, feeder characteristics and coordination with the site service supply.

Coordinate the DC battery and the external plant package

YINTU is an energy storage solution provider. We coordinate the battery container and its mechanical and electrical interfaces with the manufacturing partner. The PCS, plant EMS, transformer, switchgear and connection equipment are separate project packages. Confirm the final duty and equipment scope with the project team, including the applicable power limits for the chosen DC-to-AC arrangement.

Equipment illustration based on the existing model cover. The final service envelope and supply boundary follow the technical agreement.

Utility Scale Battery Energy Storage Systems

You May Also Like
Quality Floor Standing Residential Energy Storage Systems 16 KWh Long Lasting Home Energy Solutions factory

Floor Standing Residential Energy Storage Systems 16 KWh Long Lasting Home Energy Solutions

A 16 kWh floor-standing LiFePO4 battery with 51.2 V, 314 Ah and four casters. Standard current: 100 A; maximum continuous current: 200 A. Supports up to 15 parallel units, Bluetooth and BMS communication with a compatible external inverter.
Quality Indoor Floor Standing Residential Energy Storage Systems All In One Solar Storage For Homes factory

Indoor Floor Standing Residential Energy Storage Systems All In One Solar Storage For Homes

Floor-standing home solar storage with an integrated off-grid PV inverter and LiFePO4 battery. Four configurations offer 5.12–14.3 kWh and 5–11 kW, with direct PV input, AC charging and 230 V output. IP20 for indoor use.
Quality 12 KW / 32 KWh Stackable Home Solar Energy Storage Systems All In One ESS IP20 factory

12 KW / 32 KWh Stackable Home Solar Energy Storage Systems All In One ESS IP20

A 32 kWh stackable home ESS using 2 × 16 kWh battery modules and a 12 kW split-phase inverter. The appliance-style design combines solar input and battery storage for compatible 120 / 240 V homes.
Quality 5 KW 10.24 KWh Stackable Residential Battery Storage Systems All In One Solar ESS factory

5 KW 10.24 KWh Stackable Residential Battery Storage Systems All In One Solar ESS

A 10.24 kWh stackable home battery with an integrated 5 kW inverter, 120 V AC output and up to 6 kW PV input. The appliance-style enclosure brings solar charging and battery storage into a tidy indoor system.
Contact Us
You Can Contact Us At Anytime!